" GLAS-COL" : Fully Auto . INHALATION EXPOSURE SYSTEM(Animal Cages , µ¿¹°³ëÃâ°¨¿°½ÃÇè±â)
|
|
 |
| "
GLAS-COL" : Fully Auto . INHALATION EXPOSURE SYSTEM(Animal
Cages , µ¿¹°³ëÃâ(ÈíÀÔ)°¨¿°½ÃÇè±â) |
|
¡¡
| ¡á Á¦Á¶±¹
/
Á¦Á¶»ç |
¡á
U.S.A
/ GLAS-COL |
| ¡á»óǰ¸í |
¡á
µ¿¹°³ëÃâ(ÈíÀÔ)°¨¿°½ÃÇè±â) |
| ¡á ªÀº
¼Ò°³ |
*
¿À¿°¹°Áú°ú °¨¿°¼º±ÕÀ» ÀÌ¿ëÇÑ µ¿¹°
³ëÃâ¿¡ ´ëÇØ ³ôÀº ¾ÈÀü¼ºÀ» °¡Áü.
* ½ÇÁ¦ »óȲ°ú °¡±î¿î ÇãÆÄ °¨¿°.
* °ø±â ¼Ó º´¿ø±ÕÀÇ ³óµµ, °ø±â È帧À²,
³ëÃâ½Ã°£ µîÀÇ º¯È°¡ ÀÚÀ¯·Î¿ò.
* ½ÇÇèÀÇ ÀçÇö¼ºÀÌ Á¤È®ÇÏ¸ç ½±°Ô Á¶Á¤
°¡´É.
* Á¤È¿ë UV lamp¿Í °ø±â ¼Ò°¢·Î ÀåÂø.
* ¸Å¿ì ±â´ÉÀûÀÌ°í »ç¿ëÀÌ ½¬¿î Allen Bradley
programmable control ÀåÂø.
* Çʼö Controls¿Í Flow indicators¿Í ÇÔ²² ½Ã½ºÅÛ
³»ºÎ¿¡ ¾ÐÃà°ø±â¿Í Áø°øÆßÇÁ ÀåÂø.
|
|
¡á
Á¦
ǰ Ư ¡ (Features)
*INHALATION
EXPOSURE SYSTEM
¡á The Inhalation Exposure System provides reliable,
repeatable exposure.
¡á Provides reproducible exposure to droplet-borne
contaminants and infectious agents.
¡á Produces deep-lung infections that more closely
simulate real-world circumstances.
¡á Allows user to vary pathogen concentration, rate of
air flow, and length of exposure.
¡á Uses improved filtering, an air incinerator, and
ultraviolet lamps to aid in decontamination.
¡á Offers increased efficiency through the use of an
Allen Bradley programmable control.
* ¿À¿°¹°Áú°ú °¨¿°¼º±ÕÀ» ÀÌ¿ëÇÑ µ¿¹°
³ëÃâ¿¡ ´ëÇØ ³ôÀº ¾ÈÀü¼ºÀ» °¡Áü.
* ½ÇÁ¦ »óȲ°ú °¡±î¿î ÇãÆÄ °¨¿°.
* °ø±â ¼Ó º´¿ø±ÕÀÇ ³óµµ, °ø±â È帧À²,
³ëÃâ½Ã°£ µîÀÇ º¯È°¡ ÀÚÀ¯·Î¿ò.
* ½ÇÇèÀÇ ÀçÇö¼ºÀÌ Á¤È®ÇÏ¸ç ½±°Ô Á¶Á¤
°¡´É.
* Á¤È¿ë UV lamp¿Í °ø±â ¼Ò°¢·Î ÀåÂø.
* ¸Å¿ì ±â´ÉÀûÀÌ°í »ç¿ëÀÌ ½¬¿î Allen Bradley
programmable control ÀåÂø.
* Çʼö Controls¿Í Flow indicators¿Í ÇÔ²² ½Ã½ºÅÛ
³»ºÎ¿¡ ¾ÐÃà°ø±â¿Í Áø°øÆßÇÁ ÀåÂø.
¿ëµµ (Applications)
* º´¿ø±ÕÀ»
ÇÔÀ¯ÇÑ °ø±âÀÇ ÈíÀÔÀ» ÅëÇÑ Á¤·®Àû µ¿¹°
°¨¿° ½ÇÇè¿ë.
»ç¿ë ¿ø¸® (How
the Inhalation System works)
* ½ÇÇè¿¡ ¾µ
µ¿¹°Àº è¹ö ³» 5±¸È¹À¸·Î
³ª´µ¾îÁø ±×¹° Basket¿¡
³Ö´Â´Ù.
Basket¿¡´Â 100¸¶¸®
Áã, 15-20¸¶¸®
Guinea pig³ª
5¸¶¸®
Åä³¢°¡ µé¾î°¥ ¼ö ÀÖ´Ù.
* ¸ÕÀú ÀÌ
½Ã½ºÅÛÀÇ ½ÉÀåºÎ¶ó ÇÒ ¼ö ÀÖ´Â Nebulizer-venturi
UnitÀ» ÅëÇØ
ºÐÁøÀÌ »ðÀԵȴÙ.
* »ðÀÔµÈ
ºÐÁøÀº Compressor¿¡
ÀÇÇØ ¾ÐÃàµÈ °ø±â¿¡ ÀÇÇØ ¹Ì¸³ÀÚ·Î ¹Ù²î°í
¿©°úµÈ ½Ç³» °ø±â¿Í
È¥ÇյǾî Chamber
³»ºÎ·Î
À¯ÀԵȴÙ.
ÀÌ ¶§ ºÐÁøÀÇ Micro´ÜÀ§
À¯±âü ¼ö¸¦ º¯È½ÃÅ´À¸·Î½á ¹ÚÅ׸®¾Æ
¹è¾çÇÙ ºñÀ²À» º¯È½Ãų ¼ö ÀÖ´Ù.
ÀÌ ½Ã½ºÅÛÀº
´ÜÀ§ ½Ã°£´ç À¯ÀԵǴ °ø±âÀÇ ¾çÀ» Á¶ÀýÇÒ
¼ö ÀÖ´Ù.
* Chamber¸¦
Åë°úÇÑ ¹Ì¸³ÀÚ¿Í °ø±âÀÇ È¥ÇÕ¹°Àº UV
lamp¿Í Filter¸¦
°ÅÃÄ Á¤ÈµÇ°í
Incinerator¸¦
ÅëÇØ ¼Ò°¢µÈ ÈÄ ¿ÜºÎ·Î ¹èÃâµÈ´Ù.
¡á ±Ô°Ý
(Specifications)
|
|
|
|
|
INHALATION EXPOSURE SYSTEM
|
|
The Inhalation Exposure System provides reliable,
repeatable exposure.
-
Provides reproducible exposure to droplet-borne
contaminants and infectious agents.
-
Produces deep-lung infections that more closely
simulate real-world circumstances.
-
Allows user to vary pathogen concentration, rate of
air flow, and length of exposure.
-
Uses improved filtering, an air incinerator, and
ultraviolet lamps to aid in decontamination.
-
Offers increased efficiency through the use of an
Allen Bradley programmable control.
¡¡
|
Product
Number
|
Description
|
|
099C
A4212
|
Inhalation
Exposure System 120V, 60Hz. AC
|
|
099C
A4224
|
Inhalation
Exposure System 240V, 50Hz. AC
|
|
¡¡
| Component |
Specifications |
| Chamber |
* ¾ç±Ø »êÈ󸮵È
Aluminum tank
* Dimensions: ¥Õ22-3/4"¡¿d22"
* Volume: 5cu.ft |
| Basket |
* Stainless steelÀÇ Wire
Mesh Basket
* Dimensions : ¥Õ22"¡¿d14"
* 5°³ÀÇ ÄÀ¸·Î ³ª´µ¾îÁ® ÀÖÀ¸¸ç °¢°¢ÀÇ Ä¿¡´Â 20¸¶¸®
´µ, 3~4 ¸¶¸® Guinea pig, ¶Ç´Â Åä±â ÇѸ¶¸®°¡ µé¾î°¥ ¼ö
ÀÖÀ½.:ÃÑ 100¸¶¸® Áã, 15~20¸¶¸® Guinea pig, ȤÀº 5¸¶¸® Åä³¢ |
| Lid |
* UV ±¤¼±ÀÇ Åõ°ú¸¦
¸·´Â Åõ¸íÇÑ ¾ÆÅ©¸± ¶Ñ²±
* ³×°³ÀÇ °É¸²¼è°¡ Chamber ¶Ñ²±À» È®½ÇÇÏ°Ô ´Ý¾ÆÁÜ. |
| Cabinet |
*¹ÙÄû°¡ ´Þ¸° °ß°íÇÑ
Stainless steel Cabinet
* Flowmeters, controls, nebuilzer ÀåÂø
* Dimensions: w30"¡¿d33"¡¿h33"
* Weight: 170 lb
* ¿À¸¥ÂÊ Èĸ鿡 ¼Ò°¢·Î ÀåÂø:ÀÎÁ¢ÇÑ º®À̳ª ´Ù¸¥
Àåºñ¿ÍÀÇ °£°ÝÀÌ ÃÖ¼Ò 6"ÀÌ»óÀ̾î¾ß ÇÔ. |
| Filter |
* 0.3 micron¸ÃÅ ÀÛÀº
ÀÔÀÚ¿¡ ÃÖ¼Ò 99.97%ÀÇ È¿À²À» °¡Áö´Â À¯¸®¼¶À¯¸·ÀÇ HEPA
filter
* DOP Tested at a flow rate of 100 CFM at 1.2"w.g. |
| Controls |
* Allen Bradley programmable
controlÀÌ ³×°¡Áö Cycle(preheat, nebuilizing, cloud, decay,
decontamination)À» Á¶ÀýÇϰí È¿À²À» ³ôÀÓ.
* ÃÊ´ÜÀ§·Î DisplayµÊ. |
| Flowmeters |
* ³»±¸·Â ÀÖ°í ÆÇµ¶ÀÌ
½¬¿î µÎ°³ÀÇ Flowmeter°¡ Chamber·ÎÀÇ °ø±âÈ帧À²À»
Á¤È®ÇÏ°Ô ÃøÁ¤.
* ÃøÁ¤¹üÀ§: Compressed air line flowmeter: 2~20 SCFM, Main air
flowmeter: 10~100SCFM |
| Nebulizer |
* ¾Ð·ÂÇÏ¿¡¼ ºÐÁøÀ»
¹Ì¸³ÀÚ·Î ¸¸µé°í ½Ç³»¿¡¼ ²ø¾îµéÀÎ °ø±â¿Í ÀûÀýÇϰÔ
È¥ÇÕÇÏ¿© Chamber·Î º¸³¿. |
| Pump |
* Á¶¿ëÇÏ°í ¿ì¼öÇÑ
ǰÁúÀÇ Áø°øÆßÇÁ
* Tank¸¦ ÅëÇØ 1.67CFM ÀÌ»ó À¯¼Ó Á¶Àý |
| Incinerator |
* CabinetÀÇ ¿À¸¥ÂÊ
Èĸ鿡 ÀåÂø
* Allen Bradley Programmble Control
* ¿¹¿, ºÐ¹«, °¨¿°, Á¤È ½Ã°£À» Á¶ÀýÇϴµ¥ »ç¿ë
|
| BIONEB®
CELL DISRUPTION SYSTEM |
The
BioNeb disruption system was conceived and developed by Dr. Stefan J.
Surzycki, Dr. Robert K. Togasaki, and Mr. Masahiko Kitayama at Indiana
University Department of Molecular and Cellular Biology. Through the
regulation of gas pressure (between a range of only 10 to 250 psi), the
system can be adjusted precisely to:
- gently
open cells
- completely
disrupt cells
- achieve
90% disruption for many cells in only one or two passes
- generates
no heat - it actually cools the sample
This
efficient process takes very little time, as the unit can disrupt cells at
a flow rate of 30 ml/minute.
How
the BioNeb system works.
In
the process of droplet formation, large molecules or cells suspended in
the liquid being nebulized are forcefully distributed from the liquid into
the forming secondary droplet. This creates a transient laminar flow in
the microcapillary "nebulization" channel formed between the
surface of the liquid and the forming secondary droplet. The laminar flow
in the capillary channel exerts sufficient shearing forces to break cells.
The shearing force created depends on the gas pressure applied, the type
of gas, and the viscosity of the liquid. This makes it possible to
precisely regulate the magnitude of the force applied during nebulization.
Therefore, the same instrument can be used for very gentle opening of the
cells as necessary in organelle isolation, or for thorough breakage of the
cells when preparation of a cell extract is desired.
|
| Product
Number |
Description |
| 105A
BN3010 |
BioNeb
disruption system with cylinder for 5- to 10-ml sample volume.
Includes universal positioner. |
| 105A
BN3015 |
BioNeb
disruption system with cylinder for 10- to 30-ml sample volume.
Includes universal positioner. |
| 105A
BN3025 |
BioNeb
disruption system with cylinder for both 5- to 10-ml and 10- to
30-ml sample volumes. Include universal positioner. |
| 105A
BN4000 |
Two-stage
gas regulator for Helium or Nitrogen. 3000 psi max. inlet
pressure. 0-250 psi outlet pressure. |
Each
system includes a universal positioner and baseplate, flowmeter, 1/8"
dia. cut-to-length tubing for reservoir inlet/outlet, 12" length of
auxiliary inlet/outlet tubing, 6' length of 5/32" O.D. tubing for gas
supply, and connection fittings. (Depending on specific gas cylinders and
regulators, some additional fittings may be required.)
|
| CAT
No. |
Description |
´ÜÀ§/°¹¼ö |
Price[VATÆ÷ÇÔ] |
| GC.099CA4212 |
INHALATION,exposure
system,120V |
EA/1 |
34,173,100¿ø |
| GC.099CA4224 |
INHALATION,exposure
system,240V |
EA/1 |
35,603,600¿ø |
¡¡
¡¡ |
|
|
|
|
|
| ȨÆäÀÌÁö |
: |
http://daihanscience.koreasme.com |
| ȸ»ç¸í |
: |
http://www.daihan.net ´ëÇѰúÇבּ¸±âÀÚÀç |
| ÀüȹøÈ£ |
: |
(1)02-967-5978 ºñ»ó¿¬¶ô (H.P) : 011-768-8228 (2)02-3673-0199
|
| ÆÑ½º¹øÈ£ |
: |
(1)02-967-5979 (2)02-3673-0271
|
| ÁÖ¼Ò |
: |
(1)¼¿ïƯº°½Ã ¼ººÏ±¸ »ó¿ù°îµ¿ 24-4 ´ëÇѺôµù¼¿ï (¿ìÆí¹øÈ£: 110-123) (2)¼¿ï Á¾·Î±¸ ÀÎÀǵ¿ ¿õÁøºôµù º°°ü 210È£ (¿ìÆí¹øÈ£: 110-785) (3)¡á Åùè/ȹ°¼ºñ½º : ´ç»ç¿¡¼´Â 100,000¿ø ÀÌ»ó ±¸¸Å °í°´ ºÐ ¿¡°Ô´Â ´ç»ç¿¡¼ ºÎ´ãÇÕ´Ï´Ù ( Åùè : KGB, »ï¼º, ȹ° : ¾ç¾ç,´ë½Å,È£³²) ........................... ÁÖ°Å·¡ÀºÇà : ¡á ¿¹ ±Ý ÁÖ : ±è ¹Î ¿Á¡á ¿ì¸®ÀºÇà : 048 - 401225 - 13 - 001 ¡á ±â¾÷ÀºÇà : 086 - 023287 - 03 - 019 ¡á ±¹¹ÎÀºÇà : 045 - 24 - 0267 - 056
|
| URL |
: |
(1)http://www.daihan.net (2)http://´ëÇѰúÇÐ.net
|
| E-mail |
: |
daihansci@yahoo.co.kr |
|
|
|