" TINTOMETER" : Lovibond¢âÀû¿Ü¼± B.O.D. ÃøÁ¤ ½Ã½ºÅÛ B.O.D. IR-Transmitter-Sensomat, ET 500 & ET 510, Intelli
Á¦Ç°±¸¸Å    Á¦Ç°Ãßõ



Á¦Ç°»ç¾ç

" TINTOMETER" : Lovibond™ B.O.D. IR-Transmitter-Sensomat, ET 500 & ET 510, Intelligent B.O.D. Measuring System using IR Data Capture & Data Evaluation Software, Lovibond™ Àû¿Ü¼± B.O.D. ÃøÁ¤ ½Ã½ºÅÛ

¡á Up to 144 sets of results can be accessed with infrared 
   remote operation
¡á Variable Measuring Time from 30 Minutes to 99 Days
¡á User-friendly Means of BOD Measurement
¡á Data Evaluation Software with Statistical Functions
¡á Electronic storage ensures confidence in results
  and other measurement data
¡á Complies with GLP(Good Laboratory Practice)/ISO 9000

Ư¡ (Features)

* Respirometric Determination of Biochemical Oxygen
  Demand(B.O.D.)
* Organic substances in the sample are oxidized 
  microbially by the use of oxygen (O2). 
  The resultant carbon dioxide (CO2) is absorbed by 
  potassium hydroxide(KOH) and this results in  a pressure 
  drop in the system which is proportional to the BOD value.
  This is detected by the IR-Sensor, logged by 
  the BOD-Sensomat
  and converted directly into mg/l of BOD.
* Intelligent Measuring Systems ET 500 & ET 510 ±¸¼º :
 ¤ýIR-Sensor
    B.O.D. Bottle À§¿¡ ¶Ñ²± ÇüÅ·Π°£´ÜÈ÷ ³¢¿öÁö´Â B.O.D. 
    ÃøÁ¤ ¼¾¼­ Measurement DeviceÀÎ µ¿½Ã¿¡ Storage Unit ¿ªÇÒ
    Together with the Sample Bottle, it forms a Mobile,
    Self-contained Measuring Unit.
 ¤ýBOD-Sensomat : Portable "ore¡±of the System
    ÇѹøÀÇ ¹öư Á¶ÀÛÀ¸·Î ¸ðµç ÃøÁ¤ µ¥ÀÌÅ͸¦ ±â·Ï ¹× Á¶È¸
    °£´ÜÇϰí Àå·ÂÇÑ Evaluation ¹× Documentation ±â´É Á¦°ø
 ¤ýInductive Stirring-System 
    ÁÖ±âÀûÀÎ Acceleration°ú Stirring RodÀÇ CenteringÀ» ÅëÇÏ¿©
     Water Sample°ú Air Phase »çÀÌÀÇ ÃÖÀûÈ­µÈ Gas-exchange¸¦ º¸Àå

±Ô°Ý (Specification)

(BOD-Sensomat)
* Parameter : BOD n (DIN 38 409-H 52)
* Measuring Ranges : Programmed : 0...40 / 80 / 200 / 400 /
                    800 / 2000 / 4000 §·/§¤ B.O.D
* Test Duration : 30 Minutes to 99 Days Measurement
* Intervals : 10 Seconds to 24 Hours
* Mesurement points : 1 to 144 Operable in Parallel
* Data Storage : 180 to 360 Data-Sets(Data, Time, 
   Measurement, Identification of sample 
   & measurement point)                              
* Data security : 100% fixed
* Memory display : LCD 128 ¡¿64 Pixel / 6 rows
* Auto-Start Function : on/off switching facility, 
    measurement begins after pressure drops, or maximum 
    waiting period
* Software : Calculation of Mean, Standard Deviation, 
    exclusion of individual rogue samples
* Approval Marks : TUV/GS, CE, UL, CUL(UL/CSA)
* Degree of protection : IP42, DIN 40 050
* Batteries : 3 mignon/type AA, alkaline 1.5V,
              1 Lithium CR 2430
* Ambient temperature : (Storage) -25 ... +65¡É /
                        (Operation)+5 ... +40¡É
* Weight : Approx. 390g including Batteries
* Dimensions : L100 ¡¿w200 ¡¿h45mm

(IR-Sensor)
* Principle of Operation : Manometric/Respirometric with 
    Electronic Pressure, relative pressure measurement,
    IR-transmitter. receiver ¡¾1% of measured value ¡¾1 hPa
* Range : -500/+350 hPa(=mbar)
* Resolution : ¡¾1 hPa
* Data Storage : 180 to 360 Data-Sets(Data, Time, 
   Measurement, Identification of sample & measurement point)
* Data Security : 100% fixed
* Memory display : LED for recognition
* Batteries : 2 Lithium CR 2430(approx. 2~5 years)
* Approval Marks : TUV/GS, CE, UL, CUL(UL/CSA)
* Degree of Protection : IP 54 DIN 40 050
* Ambient Temperature : (Storage)-25¡É ... +65¡É/ 
                        (Operation)+5 ... +40¡É
* Weight : 90g including Batteries
* Dimension : ¥Õ70 mm, 70 mm in Height
CAT No. Description ´ÜÀ§/°¹¼ö Price[VATÆ÷ÇÔ]
LB.2418336 BOD SENSOMAT,ET500 SYSTEM,´ÜÁ¾ EA/1 4,997,100¿ø
LB.2418342 BOD SENSOMAT,ET510 SYSTEM,´ÜÁ¾ EA/1 8,147,300¿ø
LB.2418348 BOD SENSOMAT,REPLACEMENT,´ÜÁ¾ EA/1 8,147,300¿ø
LB.2418343 SET,SUPPLEMENTARY,´ÜÁ¾ EA/1 3,848,700¿ø
LB.2418345 SET,SUPPLEMENTARY,´ÜÁ¾ EA/1 6,772,400¿ø
LB.2418311 STIRRER,ET606 MAGNETIC,->LB.2444411 EA/1 969,800¿ø
LB.2418322 STIRRER,ET612 MAGNETIC,->LB.2444412 EA/1 1,524,800¿ø



ÀÌÀüÁ¦Ç° ¸ñ·ÏÀ¸·Î ´ÙÀ½Á¦Ç°



ȨÆäÀÌÁö : http://daihanscience.koreasme.com
ȸ»ç¸í : http://www.daihan.net ´ëÇѰúÇבּ¸±âÀÚÀç
ÀüÈ­¹øÈ£ : (1)02-967-5978 ºñ»ó¿¬¶ô (H.P) : 011-768-8228
(2)02-3673-0199
ÆÑ½º¹øÈ£ : (1)02-967-5979
(2)02-3673-0271
ÁÖ¼Ò : (1)¼­¿ïƯº°½Ã ¼ººÏ±¸ »ó¿ù°îµ¿ 24-4 ´ëÇѺôµù¼­¿ï (¿ìÆí¹øÈ£: 110-123)
(2)¼­¿ï Á¾·Î±¸ ÀÎÀǵ¿ ¿õÁøºôµù º°°ü 210È£ (¿ìÆí¹øÈ£: 110-785)
(3)¡á Åùè/È­¹°¼­ºñ½º : ´ç»ç¿¡¼­´Â 100,000¿ø ÀÌ»ó ±¸¸Å °í°´ ºÐ ¿¡°Ô´Â ´ç»ç¿¡¼­ ºÎ´ãÇÕ´Ï´Ù ( Åùè : KGB, »ï¼º, È­¹° : ¾ç¾ç,´ë½Å,È£³²) ........................... ÁÖ°Å·¡ÀºÇà : ¡á ¿¹ ±Ý ÁÖ : ±è ¹Î ¿Á¡á ¿ì¸®ÀºÇà : 048 - 401225 - 13 - 001 ¡á ±â¾÷ÀºÇà : 086 - 023287 - 03 - 019 ¡á ±¹¹ÎÀºÇà : 045 - 24 - 0267 - 056
URL : (1)http://www.daihan.net
(2)http://´ëÇѰúÇÐ.net
E-mail : daihansci@yahoo.co.kr