ȸ»ç¼Ò°³Á¦Ç°¼Ò°³±â¼úÇöȲMy page´ëÇ¥ÀÚÀλ縻»ý»êÇöÀåOEM


 
ADDMENU1
±¸¸Å»ó´ã
 





°Ô½ÃÆÇ
Á¦Ç°±¸¸Å
 



" Micronic" : TraXis¢â and Tracker¢â Systems, Sample Readers, Sample ÆÇµ¶±â TraXis¢â and Tracker¢â, CE-Mark
Á¦Ç°±¸¸Å    Á¦Ç°Ãßõ



Á¦Ç°»ç¾ç

  

" Micronic" : TraXis™ and Tracker™ Systems, Sample Readers, Sample ÆÇµ¶±â TraXis™ and Tracker™, CE-Mark

¡á No More Hassles and Confusions to handle your valuable samples
¡á TraXis™ and Tracker™ Readers provides the ideal solution to users who do
not have HT requirements or wish to gain the benefits of coded tubes
prior to the installation of a tube based storage system.
¡á TraXis/Tracker Readers: read 96 tubes simultaneously, 96 tubes read
within 3 seconds, a reader for every application, systems tailored to
the user requirements, operation of both HTM and TM standard a complete
software.
¡á TraXis/Tracker Software: simple to install and operate, output file
(CSV or directly to Excel), Windows NT/2000, applicable with Tracker
code and rack barcode.

The expanding storage needs of modern laboratories have created the
requirements for a reliable method of sample storage, retrieval and
confirmation. Understanding this micronic has developed Traxis a new
tube based storage system with 8.5 billions code combination,
that offers the highest sample security and traceability for laboratory
applications. In life science laboratories where sample storage and
recovery must be 100% reproducible in Traxis system ensures that samples can
always be located whatever their location. Traxis reader will function
on most PCs within laboratories.

Ư¡ (Features)
* TraXis / Tracker Readers´Â High-throughput(´ë·®»ùÇÃÆÇµ¶)ȯ°æÀÌ °®Ãß¾îÁöÁö
¸øÇÑ »ç¿ëÀÚµéÀ̳ª, ´ë·®È­µÈ »ùÇà tubeÀÇ ÀÌ»óÀû ÀúÀå/°ü¸®¸¦ Àý´ëÀûÀ¸·Î ¿ä±¸ÇÏ´Â
»ç¿ëÀÚµéÀ» À§ÇØ °³¹ßµÈ ƯÀÌÀûÀ¸·Î ¾ÏȣȭµÈ tube¸¦ ÀνÄ/ÀúÀå/°ËÁõÇÏ¿© ÁÖ´Â ÃÖ÷´Ü ÆÇµ¶
±â±âÀÓ.
* TraXis / Tracker ÆÇµ¶ ÀåÄ¡´Â µ¿½Ã¿¡ 96°³ÀÇ Tube¸¦ ÀνÄÇϰí, ´Ü 3 Ãʸ¸¿¡ 96°³ÀÇ
»ùÇÃÀ» ÆÇµ¶ ÇÏ¿©, »ç¿ëÀÚÀÇ ¿ä±¸Á¶°ÇÀ» ÃÖÀûÈ­ ÇÑ ¸ðµç ÀÀ¿ëºÐ¾ß¿¡ Ȱ¿ëÀÌ °¡´ÉÇÑ
ÆÇµ¶±âÀ̸ç, Ç¥ÁØÈ­µÈ ÄÄÇ»ÅÍ ¼ÒÇÁÆ®¿þ¾î¸¦ Æ÷ÇÔÇÑ ´ë·®È­Çü(HTM)°ú Å×À̺íÇü(TM)ÀÌ
°ø±ÞµË´Ï´Ù.
* TraXis / Tracker ÆÇµ¶±â´Â ÀåÄ¡¿Í µ¿ÀÛÀÌ °£´ÜÇϸç, ÄÄÇ»ÅÍ ¼ÒÇÁÆ®¿þ¾î¸¦ ÀÌ¿ëÇÏ¿©
CSV ÆÄÀÏÀ̳ª Excel ÆÄÀÏ·Î µ¥ÀÌÅ͸¦ ÀúÀåÇϰí, Windows NT/2000 ½Ã½ºÅÛ¿¡¼­ ÀÌ¿ë
°¡´ÉÇϸç, Tacker ÄÚµåÈ­µÈ tube¿Í rack barcode¸¦ °¨ÁöÇϵµ·Ï °í¾ÈµÊ.

Micronic»ç ¼Ò°³ (Introduction of Micronic Company)
ÃÖ÷´Ü ½ÇÇè½Ç¿¡¼­ÀÇ Á¡Á¡ ´ë·®È­ µÇ¾î°¡°í ÀÖ´Â »ùÇõéÀÇ È¿À²ÀûÀÎ °ü¸®, °ËÁõ, ±¸º°,
ÀúÀå ±â¼úÀÇ Çʿ伺ÀÇ ¿ä±¸ÃæÁ·À» À§ÇØ Micronic»ç´Â ¾ÏȣȭµÈ ÃÖ÷´Ü Tube
(¹«·Á 85,000,000 ÄÚµå·Î ÀçÁ¶ÇÕ)¸¦ °³¹ßÇÏ¿©, ½ÇÇè½Ç ³»¿¡¼­ ¾î¶² ÀÀ¿ëºÐ¾ß¿¡¼­µµ »ç¿ëÀÚÀÇ
»ùÇÃÀÇ ÃÖ°íÀÇ º¸¾È¼º°ú °¨Áö Ư¼ºÀ» °¡Áø ÀÚµ¿È­ Àåºñ¸¦ °ø±ÞÇÏ°Ô µÊ. ƯÈ÷, ±ÍÁßÇÑ »ý¹°ÇÐÀû
½Ã·á³ª »ùÇÃÀÇ ÀúÀå/°ü¸®¿Í º¹±¸°¡ ¿ä±¸µÇ´Â »ý¸í°úÇÐ ¿¬±¸½Ç ³»¿¡¼­´Â Micronic»çÀÇ
TraXis systemÀ» ÀÌ¿ëÇÔÀ¸·Î½á »ç¿ëÀÚÀÇ »ùÇÃÀÇ ÈѼվø´Â 100% Àç»ýÀ» º¸ÁõÇÔ. ¶ÇÇÑ,
º» ÆÇµ¶ ÀåÄ¡µéÀº »ç¿ëÀÚÀÇ ÆíÀǸ¦ µµ¸ðÇÏ¿© ½ÇÇè½Ç¿¡ ÀåÂøµÈ ±âÁ¸ PCµé°ú ȣȯ,
¿¬°á °¡´ÉÇϵµ·Ï Á¦ÀÛ µÊ.

»ç¿ë¿µ¿ª ¹× Àû¿ëºÐ¾ß (Main areas of use)
¨ç TraXis/Tracker HTM : High-throughput(´ë·®»ùÇÃÆÇµ¶/°ËÁõ), ºÐ¼®È­ÇÐ ½ÇÇè½Ç, ´ë·®ÀÇ
»ý¹°ÇÐÀû ½Ã·á³ª »ùÇÃÀ» Ãë±ÞÇÏ´Â »ç¿ëÀÚµéÀ» À§ÇÑ ¼±Åà (Drug-screening, testing)
¨è TraXis/Tracker TM : º¥ÃëÇü ÆÇµ¶±â·Î½á Small compound libraries,
µ¿¹°½ÇÇè ¿¬±¸¼Ò, º´¿ø ¿¬±¸¼Ò, ¼Ò±Ô¸ð ±â¾÷ ¿¬±¸½Ç¿¡ ÀûÇÕÇÑ Àú·ÅÇÑ ¼±ÅÃ.
¨é Traxis/Tracker STM : Weighing station (on line), Liquid handling station,
High volume storage system (on line), RackÀ» »ç¿ëÇÏÁö ¾Ê´Â »ùÇõéÀÇ
¾ÏÈ£ °ËÁ¤ ½Ã, Áö±ØÈ÷ °í°¡ÀÇ Áß¿äÇÑ ¼Ò·®»ùÇà ÀÇ »ç¿ëÀÚ(off-line), ¼ÒÇÁÆ®¿þ¾î°¡ ÀåÂø.
¨ê PC/¼ÒÇÁÆ®¿þ¾î¸¦ ÀÌ¿ë : ÀÚµ¿À¸·Î TraXis ÄÚµå¿Í Rackbarcode¸¦ ÀνÄ, BarcodeÈ­µÈ
TubeµéÀº High volume »ç¿ëÀÚ, ƯÈ÷ TraXis ÀÌ¿ëÀÚ°¡ ¾Æ´Ñ °æ¿ì¿¡µµ À̿밡´É.
CAT No. Description ´ÜÀ§/°¹¼ö Price[VATÆ÷ÇÔ]
MI.M55001 SAMPLE READER,TRAXIS,HTM EA/1 120,223,500¿ø
MI.M55002 SAMPLE READER,TRAXIS,STM IN-LINE EA/1 24,290,100¿ø
MI.M55003 SAMPLE READER,TRAXIS,STM OFF-LINE EA/1 9,049,900¿ø
MI.M55004 SAMPLE READER,TRAXIS,TM EA/1 6,627,500¿ø
MI.M55101 SAMPLE READER,TRACKER,HTM EA/1 120,223,500¿ø
MI.M55103 SAMPLE READER,TRACKER,STM OFF-LINE EA/1 9,049,900¿ø
MI.M55104 SAMPLE READER,TRACKER,TM EA/1 6,627,500¿ø



ÀÌÀüÁ¦Ç° ¸ñ·ÏÀ¸·Î ´ÙÀ½Á¦Ç°



ȨÆäÀÌÁö : http://daihanscience.koreasme.com
ȸ»ç¸í : http://www.daihan.net ´ëÇѰúÇבּ¸±âÀÚÀç
ÀüÈ­¹øÈ£ : (1)02-967-5978 ºñ»ó¿¬¶ô (H.P) : 011-768-8228
(2)02-3673-0199
ÆÑ½º¹øÈ£ : (1)02-967-5979
(2)02-3673-0271
ÁÖ¼Ò : (1)¼­¿ïƯº°½Ã ¼ººÏ±¸ »ó¿ù°îµ¿ 24-4 ´ëÇѺôµù¼­¿ï (¿ìÆí¹øÈ£: 110-123)
(2)¼­¿ï Á¾·Î±¸ ÀÎÀǵ¿ ¿õÁøºôµù º°°ü 210È£ (¿ìÆí¹øÈ£: 110-785)
(3)¡á Åùè/È­¹°¼­ºñ½º : ´ç»ç¿¡¼­´Â 100,000¿ø ÀÌ»ó ±¸¸Å °í°´ ºÐ ¿¡°Ô´Â ´ç»ç¿¡¼­ ºÎ´ãÇÕ´Ï´Ù ( Åùè : KGB, »ï¼º, È­¹° : ¾ç¾ç,´ë½Å,È£³²) ........................... ÁÖ°Å·¡ÀºÇà : ¡á ¿¹ ±Ý ÁÖ : ±è ¹Î ¿Á¡á ¿ì¸®ÀºÇà : 048 - 401225 - 13 - 001 ¡á ±â¾÷ÀºÇà : 086 - 023287 - 03 - 019 ¡á ±¹¹ÎÀºÇà : 045 - 24 - 0267 - 056
URL : (1)http://www.daihan.net
(2)http://´ëÇѰúÇÐ.net
E-mail : daihansci@yahoo.co.kr