" KERN" : ÀüÀÚµ¿ Àû¿Ü¼± ¼öºÐÃøÁ¤±â, Fully Automatic Moisture Analyzer, Precision ¡°RH¡±, with Infrared Dryer
Á¦Ç°±¸¸Å    Á¦Ç°Ãßõ



Á¦Ç°»ç¾ç

" KERN" : Fully Automatic Moisture Analyzer, Precision ¡°RH¡±, with Infrared Dryer / Balancing, Digital Display 1 mg ¡­ 120 g, 0 ¡­ 100 %, ÀüÀÚµ¿ Àû¿Ü¼± ¼öºÐÃøÁ¤±â, Digital Á¤¹ÐÇü, CE / DKD / ISO ÀÎÁõ

Application & Feature / ¿ëµµ ¹× Ư¡ :

* ±¤¹üÀ§ÇÑ ¿ëµµ :
  ¼öºÐ ÃøÁ¤ÀÌ ÇÊ¿äÇÑ ¸ðµç ¹°Ã¼(½Ã·á ¹«°Ô 120 g ÀÌÇÏ)ÀÇ ÇÔÀ¯µÈ ¼öºÐÀ» ÃøÁ¤ÇϰíÀÚ 
  ÇÒ ¶§ »ç¿ëµÊ.
* ƯÈ÷ ½Äǰ, ÀǾàǰ, È­ÇÐ, µµ·á, ³ó¾÷, ºÐü »ê¾÷ ºÐ¾ß¿¡ ÀûÇÕ 
  (Laboratory & Industry)
* Àû¿Ü¼±(Infrared) °¡¿­ °ÇÁ¶¿¡ ÀÇÇØ¼­ ¼öºÐÀÇ ¾ç ¹× ½Ã·áÀÇ ¹«°Ô ÃøÁ¤ :
  1 mg ¡­ 120 gÀÇ ½Ã·á, 0 ¡­ 100 % Humidity
* Application-Table Á¦°ø :
  »ç¿ë ºÐ¾ßº° ¹× ¿©·¯ ´Ù¾çÇÑ ½Ã·áÀÇ Á¾·ùº° ½ÃÇè¹ýÀ» °£°áÇÏ°í ½±°Ô Á¤¸®ÇÑ »ç¿ëµµÇ¥ 
  ÇÔ²² °ø±Þ
* Humidity Efficient Construction / Design :
  - Two infrared quartz crystal emitters 410 W.
  - Sighthole for sight over sample, extremely useful during initial 
    adjustment
  - Last value measured remains on display until being overwritten
    by new measurement.
  - Only 4 keys and simple user prompts on display.
* Data-Network System :
  RS-232C Interface for Optical Printer(KE.911010) or PC
* Æ¢±â°Å³ª Open ½Ãų ¼ö ¾ø´Â ½Ã·áÀÇ SamplingÀ» À§ÇÑ ´Ù°ø¼º 
  Round Fiberglass Filter(KE.RHA02)°¡ OptionÀ¸·Î °ø±ÞµÊ. 30 Piece Alum.
  Sample Dish Æ÷ÇÔ.
* Drying Sequence / Switch-off Criteria :
  - Fully Automatic : Drying to Constant Weight.
  - Semiautomatic : Drying ends when loss per unit of time goes below 
    theoritical value.
  - Manual : According to Adjusted Time. -1 ¡­ 200 min
    Check of Measure Value : Interval Adjust.    Of 0.1 ¡­ 10 min

Technical Specifications / ¼¼ºÎ ±â¼ú ÀÚ·á:

* Weighing System with KE.822 Balance : 120 g, 1 mg
* Dry Measurement Values:
  - Read out : 0.01 %
  - Repeatability, Weight 1 g  : 0.2 %
  - Repeatability, Weight 10 g : 0.02 %
* Display after Drying:
  - % Humidity = Weight Reduction : 0 ¡­ 100 %
  - % Dry Mass = Residual Weight  : 100 ¡­ 0 %
  - ATRO :100 ¡­ 999 %
  - Gr. Humidity = Liquid Substances / Weight Reduction
  - Gr. Dry Mass = Solid Substances / Residual Weight
* Heater / Temperature Adjustment :
  - Temperature Range 40 ¡­ 250 ¡ÉIn Steps of 1 ¡É
  - Fixed Heating Stages (Constant Heat)  :  20
  - Pre-Heating Stage to Reduce Drying Time  :  1 ¡­ 99 min.

CAT No. Description ´ÜÀ§/°¹¼ö Price[VATÆ÷ÇÔ]
KE.RH120.3 MOISTURE,ANALYZER,1MG-120G EA/1 4,163,600¿ø



ÀÌÀüÁ¦Ç° ¸ñ·ÏÀ¸·Î



ȨÆäÀÌÁö : http://daihanscience.koreasme.com
ȸ»ç¸í : http://www.daihan.net ´ëÇѰúÇבּ¸±âÀÚÀç
ÀüÈ­¹øÈ£ : (1)02-967-5978 ºñ»ó¿¬¶ô (H.P) : 011-768-8228
(2)02-3673-0199
ÆÑ½º¹øÈ£ : (1)02-967-5979
(2)02-3673-0271
ÁÖ¼Ò : (1)¼­¿ïƯº°½Ã ¼ººÏ±¸ »ó¿ù°îµ¿ 24-4 ´ëÇѺôµù¼­¿ï (¿ìÆí¹øÈ£: 110-123)
(2)¼­¿ï Á¾·Î±¸ ÀÎÀǵ¿ ¿õÁøºôµù º°°ü 210È£ (¿ìÆí¹øÈ£: 110-785)
(3)¡á Åùè/È­¹°¼­ºñ½º : ´ç»ç¿¡¼­´Â 100,000¿ø ÀÌ»ó ±¸¸Å °í°´ ºÐ ¿¡°Ô´Â ´ç»ç¿¡¼­ ºÎ´ãÇÕ´Ï´Ù ( Åùè : KGB, »ï¼º, È­¹° : ¾ç¾ç,´ë½Å,È£³²) ........................... ÁÖ°Å·¡ÀºÇà : ¡á ¿¹ ±Ý ÁÖ : ±è ¹Î ¿Á¡á ¿ì¸®ÀºÇà : 048 - 401225 - 13 - 001 ¡á ±â¾÷ÀºÇà : 086 - 023287 - 03 - 019 ¡á ±¹¹ÎÀºÇà : 045 - 24 - 0267 - 056
URL : (1)http://www.daihan.net
(2)http://´ëÇѰúÇÐ.net
E-mail : daihansci@yahoo.co.kr