Tuttnauer" : Fully Auto. Steam
Sterilizers
Tuttnauer Bench-top
autoclave 7.5, 23,
62, 85, 110, 160 Lit.,
with Self-Locking, Double-wall &
Stainless Chamber, Ãʰ·Â
ÀüÀÚµ¿ ¸ê±Õ±â, ÀÚµ¿Àá±Ý/Áø°ø°ÇÁ¶Çü,
Highest-Quality/Safety |
|
|
|
Tuttnauer Bench-top autoclave
Remote sensor : sampleÀÇ ¿Âµµ¸¦ Á÷Á¢ ÃøÁ¤, Validation ¿ëÀÌ
Full Validation Package IQ, OQ and PQ
Options and accessories Documentation
*Printer
- For documenting all programme data- batch number, date, time,
temperature, pressure, sterilisation phase.
RS 422 interface
-For connection to an external data system, e.g. PC .
PC software
- For Windows/Windows 95, for documentation of programme data- batch
number, date, time, temperature, pressure, sterilisation phase, both
analogous (diagrams) and digital
Cooling
*Rapid cooling
- Via water-cooled coils, optionally with or without support pressure
with sterilefiltered compressed air. Up to 70% time saving compared with
natural cooling.
Circulation cooler
- For coil cooling systems to save cooling water.
Water-softener
- Necessary if water is harder than 10 ¡Æ.
Build in ventilator
- With drive via magnetic gear to optimise the effectiveness of the coil
cooling. Up to 90 % time-saving compared to natural cooling.
Spray cooling
- Via recirculation of sterilised feed water. Cooling is via heat
exchanger and subsequent spraying of sterile vessels with the cooled
sterile water under support pressure via sterile-filtered compressed
air. Over 90 % time saving compared with natural cooling.
Steel laminar sheet
- Necessary for spray cooling if the sterile vessels may not be sprayed
directly.
Air compressor
- For support pressure in rapid cooling procedures if no compressed air
supply is available. Build in ventilator
System accessories
Exhaust filtration
During the heating- and sterilisation phase, including filter cartridge,
when sterilising highly infectious material.
Vacuum equipment
*With water ring pump, for pre- and post-vacuum generation for improved
air exhaust from the sterilisation chamber and effective drying.
With swivel arm, for inserting heavy goods into vertical autoclaves.
Heating with external steam supply
For using external steam source for heating purposes instead of
electrical heating.
Steam generator
With feed water pump, instead of self generation of steam.
Condensate vessel
A 25-l vessel with steel dip tube and connecting hose. For vertical
autoclaves if no drain is available.
Ion exchange cartridge
Made of steel, for feed water supply if no demineralised water supply is
available.
Support-table
Made of stainless steel, for all bench-top autoclaves.
* For series EL and ELV only.
|
| ´Ù¾çÇÑ ¿ë·®±¸ºñ : 7.5, 23,
62, 85, 110, 160 L |